AEW – Allied Engineering Works Pvt. Ltd.

PVC Unarmoured Cables

Cable Structure
ConductorMaterial – Copper According to VDE 0295 class 1 or 2 (IEC 60228,IS 8130)
InsulationPVC Type A of IS:5831
Inner SheathPVC
ArmouringSingle layer of GS round wire or Flat Strips
Outer SheathPVC TYPE ST-1 OF IS : 5831
APPLICATIONS

PVC Unarmoured Cables
Power cables for energy supply are installed outdoors, in underground, in water, indoors, in cable ducts, power stations, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not to be expected.

Standard length cable packing:
Coils 100, 200, 300, 500, 1000 m. in wooden reels

COLOR CODING: AS IEC 60502 PART-1, B.S. 6346
Single core2 Core3 Core4 Core5 Core
Black or Yellow/GreenBlue and Brown or Yellow-Green and BlackBrown, Black, Grey or Yellow/Green, Blue, BrownBlue, Brown, Black, Grey or Yellow/Green, Brown, Black, GreyBlue, Brown, Black, Grey, Black or Yellow/Green, Blue, Brown, Black, Grey
AEW 1.1 kV 3 CORE COPPER CONDUCTOR PVC INSULATED , INNER SHEATHED UN ARMOURED PVC SHEATHED CABLES (IS : 1554 PART 1 )
CABLE CODE : YY
SIZE (MM2)INSULATION PVC THICKNESS IN MM (NOM.)INNER SHEATH PVC THICKNESS IN MM (MIN.)OUTER SHEATH PVC THICKNESS IN MM (MIN.)APPROX OUTER SHEATH O/D IN MMAPPROX WEIGHT OF CABLE (KGS./KM)MAX.DC CONDUCTOR RESISTANCE at
20° C (Ohm/Km)
Current Ratings (Amp.)
Direct
In
Ground
In Air
3 C X 1.50.800.301.8011.6020112.102117
3 C X 2.50.900.301.8012.802567.412724
3 C X 41.000.301.8014.953654.613630
3 C X 61.000.301.8016.004473.084539
3 C X 101.000.301.8018.156231.836052
3 C X 161.000.302.0020.708771.157766
3 C X 251.200.302.0021.3011380.7279990
3 C X 351.200.302.0023.2514720.524120110
3 C X 501.400.302.0026.5520270.387145135
3 C X 701.400.402.2029.6526580.268175165
3 C X 951.600.402.2033.6035740.193210200
3 C X 1201.600.402.2036.2544090.153240230
3 C X 1501.800.502.4040.4054840.124270265
3 C X 1852.000.502.4044.0066320.0991300305
3 C X 2402.200.602.6049.2084120.0754345355
3 C X 3002.400.602.8054.30104340.0601385400
3 C X 4002.600.703.2061.70138230.0470425455
AEW 1.1 kV 4 CORE COPPER CONDUCTOR PVC INSULATED , INNER SHEATHED UN ARMOURED PVC SHEATHED CABLES (IS : 1554 PART 1 )
CABLE CODE : YY
SIZE (MM2)INSULATION PVC THICKNESS IN MM (NOM.)INNER SHEATH PVC THICKNESS IN MM (MIN.)OUTER SHEATH PVC THICKNESS IN MM (MIN.)APPROX OUTER SHEATH O/D IN MMAPPROX WEIGHT OF CABLE (KGS./KM)MAX.DC CONDUCTOR RESISTANCE at
20° C (Ohm/Km)
Current Ratings (Amp.)
Direct
In
Ground
In Air
4 C X 1.50.800.301.8012.5023512.102117
4 C X 2.50.900.301.8013.803037.412724
4 C X 41.000.301.8016.254384.613630
4 C X 61.000.301.8017.455413.084539
4 C X 101.000.302.0020.257821.836052
4 C X 161.000.302.0022.9010951.157766
4 C X 251.200.302.0025.3513610.7279990
4 C X 351.200.302.0027.8517700.524120110
4 C X 501.400.302.2032.4024690.387145135
4 C X 701.400.402.2035.8532110.268175165
4 C X 951.600.402.4041.2543580.193210200
4 C X 1201.600.402.4044.7053860.153240230
4 C X 1501.800.502.6049.5566640.124270265
4 C X 1852.000.502.8054.7081340.0991300305
4 C X 2402.200.603.0060.90102750.0754345355
4 C X 3002.400.603.4067.90128380.0601385400
4 C X 4002.600.703.6076.75169190.0470425455