AEW

CONSTRUCTION

ConductorFinely stranded bare flexible copper conductor
InsulationPVC
SheathPVC (sheath 1 & 2)
Core Colours3core : Red, Yellow, Blue OR Brown, Blue, Black
  4core: Red, Yellow, Blue, Green OR Brown, Blue, Black, Yellow with Green line OR Green with Yellow line

For Equipment used in the following applications

  • Irrigation
  • Drinking water-supply
  • Industries
  • Mine De-watering
  • Offshore Drilling Rigs
  • Sewage Treatment Plant
  • Sea Water Handling
  • Fire Fighting
ConductorPVC InsulationPVC SheathConductor
Resistance
at 20°C (Max)
ohms/km
Current
Rating at
40°C Amps.
Nominal
Size in
Nos. &
Dia of Wire
Nominal
Thickness
Nominal
Core Dia.
Nominal
Thickness
Approx. Overall
Dimensions
Sq. mm.Nos./mmmmmmmmHeight
mm
Width
mm
0.516/0.20.600.902.204.308.9039.004
0.7524/0.20.600.902.454.509.5026.007
1.0014/0.30.600.902.704.7010.2018.1012
1.5022/0.300.600.902.804.9010.5012.1014
2.5036/0.300.701.003.505.7012.607.4118
4.0056/0.300.801.004.106.6014.804.9526
6.0084/0.300.801.105.107.4017.703.3031
10.00140/0.301.001.406.309.3022.301.9142
16.00224/0.301.001.407.5010.8026.301.2157
25.00350/0.301.202.0010.1014.7035.500.78072
35.00490/0.301.202.0011.3016.8039.500.55490
50.00703/0.301.402.2013.5018.0045.500.386115
70.00988/0.301.402.2015.3020.0051.000.272143
95.001349/0.301.602.4018.0023.5060.000.206165
ConductorPVC InsulationPVC SheathConductor
Resistance
at 20°C (Max)
ohms/km
Current
Rating at
40°C Amps.
Nominal
Size in
Nos. &
Dia of Wire
Nominal
Thickness
Nominal
Core Dia.
Nominal
Thickness
Approx. Overall
Dimensions
Sq. mm.Nos./mmmmmmmmHeight
mm
Width
mm
1.5022/0.300.803.251.306.2015.8012.1014
2.5036/0.300.903.801.306.4018.007.4118
4.0056/0.301.004.501.157.4021.004.9526
6.0084/0.301.005.251.508.0024.503.3031
10.00140/0.301.006.501.809.9029.701.9142
16.00224/0.301.008.001.9511.8036.001.2157
25.00350/0.301.2010.102.0014.7045.100.78072
35.00490/0.301.2011.302.0016.8050.100.55490
50.00703/0.301.4013.302.2018.3058.100.386115
70988/0.301.4015.302.2020.0066.500.272143
951349/0.301.6018.002.4023.5077.300.206165
120.00608/0.501.8019.803.5027.4087.000.161188
Operating Temp. -20°C to max.+70°C
Nominal voltage 1100 V
Test voltage 3000 V
Min. bending radius 6 x cable diameter
Flame propagation Flame retardant test per IEC 60332-1

Note:

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360
  • In view of continuous improvements in our design and process, specifications given here in are subject change without notice.