AEW

STRUCTURE

Generally Conforms to, DIN VDE 0282 PART 810, IEC 245, BS7655,BS7919/ HD22.1, HD22.4

ConductorFlexible Class 5 copper conductor according to DIN VDE 0295,IEC 60228
InsulationEPDM-rubber, core identification by colours
SheathingWeather – and oil resistant rubber Black or Blue,

HO7RN-F
JAINSON H07RN-F rubber insulated and sheathed cables are intended for flexible connection to electrical equipment. They are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites.

Standard length cable packing:
Coils 100 and 200 m in carton boxes, reels

Operating Temp-25°c to max.+90°C
Nominal voltage450/750 V
Test voltage2500 V
Min. bending radius8 x cable diameter
Flame propagationFlame retardant test as per IEC 60332-1
Sq. mmNos/ dia. (Nom.)Insulation Thicknes
in mm ( nom.)
Core dia. In mmSheath Thickness
in mm (nom.)
Cable dia.
In mm (Nom.)
Max. C.R in
ohm/km Copper
1 C X 1.522/0.3000.803.251.406.2012.10
1 C X 2.536/0.3000.803.801.406.707.41
1 C X 456/0.3000.904.501.507.504.95
1 C X 684/0.3001.005.251.608.603.30
1 C X 10140/0.3001.007.001.8010.801.91
1 C X 16224/0.3001.208.151.9012.201.21
1 C X 25350/0.3001.209.952.0014.200.780
1 C X 35490/0.3001.4011.102.2015.700.554
1 C X 50703/0.3001.4013.302.4018.300.386
1 C X 70988/0.3001.6015.152.6020.600.272
1 C X 951349/0.3001.6017.552.8023.400.206
1 C X 120608/0.5001.8019.453.0025.700.161
1 C X 150760/0.5002.0021.303.2027.900.129
1 C X 185943/0.5002.2023.903.4030.800.106
1 C X 2401225/0.5002.4027.103.5034.100.0801
1 C X 3001498/0.5002.6029.603.6036.800.0641
1 C X 4002035/0.5002.8033.803.8041.600.0486

Note:

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 or UL83
Sq. mmNos/ dia. (Nom.)Insulation Thicknes
in mm ( nom.)
Core dia. In mmSheath Thickness
in mm (nom.)
Cable dia.
In mm (Nom.)
Max. C.R in
ohm/km Copper
2 C X 114/0.3000.803.001.308.7018.1
2 C X 1.522/0.3000.803.251.509.6012.10
2 C X 2.536/0.3000.903.801.7011.107.41
2 C X 456/0.3001.004.501.8012.904.95
2 C X 684/0.3001.005.252.0014.703.30
2 C X 10140/0.3001.206.503.1019.401.91
2 C X 16224/0.3001.208.003.3022.701.21
2 C X 25350/0.3001.4010.103.6027.500.780

Note:

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 or UL83
Sq. mmNos/ dia. (Nom.)Insulation
Thicknes
in mm ( nom.)
Core dia.
In mm
Sheath Thickness
in mm (nom.)
Cable dia.
In mm (Nom.)
Max. C.R in
ohm/km
Copper
3 C X 114/0.3000.8031.49.45
3 C X 1.522/0.3000.803.251.610.2012.10
3 C X 2.536/0.3000.903.801.811.907.41
3 C X 456/0.3001.004.501.9013.504.95
3 C X 684/0.3001.005.252.1015.603.30
3 C X 10140/0.3001.206.503.3020.601.91
3 C X 16224/0.3001.208.003.5024.201.21
3 C X 25350/0.3001.4010.103.8029.100.780
3 C X 35490/0.3001.4011.304.1032.100.554
3 C X 50703/0.3001.6013.304.5038.100.386
3 C X 70988/0.3001.6015.304.8042.300.272
3 C X 951349/0.3001.8018.005.3049.100.206
3 C X 120608/0.5002.0019.805.9054.600.161
3 C X 150760/0.5002.2022.006.0059.500.129
3 C X 185943/0.5002.40023.706.5064.300.106

Note :


  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 or UL83
Sq. mmNos/ dia. (Nom.)Insulation Thicknes in mm ( nom.)Core dia. In mmSheath Thickness in mm (nom.)Cable dia. In mm (Nom.)Max. C.R in ohm/km Copper
4 C X 114/0.3000.803.001.510.718.1
4 C X 1.522/0.3000.803.251.7011.212.10
4 C X 2.536/0.3000.903.801.9013 7.41
4 C X 456/0.3001.004.502.0014.94.95
4 C X 684/0.3001.005.252.3017.53.30
4 C X 10140/0.3001.206.503.4022.61.91
4 C X 16224/0.3001.208.003.6027.11.21
4 C X 25350/0.3001.4010.104.1032.70.780
4 C X 35490/0.3001.4011.304.4036.20.554
4 C X 50703/0.3001.6013.304.8042.30.386
4 C X 70988/0.3001.6015.305.2048.20.272
4 C X 951349/0.3001.8018.005.9055.60.206
4 C X 120608/0.5002.0019.806.0061.20.161
4 C X 150760/0.5002.2022.006.5066.000.129
4C X 185943/0.5002.4023.706.9071.50.106

Note :

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 or UL83