AEW

CABLE STRUCTURE

ConductorFine Stranded Copper (Class 5 – Flexible Plain Copper) to VDE 0295 IEC 60228
InsulationHO5VVF : PVC
HO5V2V2F : Heat Resistant PVC
ColourWhite, Black, Blue or as per party order
Operating TempH05VV-F -20°c to +80°C
H05V2V2-F -20°c to +90°C
Nominal voltageH05VV-F : 300/500 V
H05V2V2-F : 450/750 V
Test voltageH05VV-F : 2.5KV
H05V2V2-F : 2.5KV
Insulation resistanceMin. 20 MΩ x km
Min. bending radius7 x cable diameter

H05VV-F, H05V2V2-F
H05VV-F AND H05V2V2-F cordage is a flexible PVC insulated, PVC jacketed harmonized cord recommended for use in electronic and electrical equipment such as office.

Standard length cable packing:
100, 200, 500, 1000 m. in reels

  • Special heat resistant insulation
  • High current carrying capacity
  • Less heat energy radiation
  • Longer flex life
  • High compatibility of cores
  • Excellent resistant to moisture, abrasion, grace, oil
  • Excellent mechanical & electrical properties
  • Insulation is highly thermal stable
  • Harmonized acc. to European standards
  • Tested by SGS, EIL, RITES, NPC, INTERTEK
Nom. Sq.AreaCopper ConfigurationNominal insulation thicknessNominal Sheath Thickness in mmAppx.overall Diameter in mmMax Conductor Resistance at 20°C
2 core3 core4 core5 core2 core3 core4 core5 core
sq mmNos/ mm. (Nom.)mmmmmmmmmmmmmmmmmmΩ/km
0.7524/0.2000.600.800.800.800.906.206.507.108.0026.00
132/0.2000.600.800.800.900.907.207.608.509.3019.50
1.530/0.2500.700.800.901.001.107.808.459.5010.5513.30
2.550/0.2500.801.001.001.101.209.409.9511.1012.357.98
456/0.3000.801.101.201.201.4010.6011.4012.5014.104.95
  • All are class 5 flexible conductor
  • Insulation grade is TI2
  • Sheathing grade is TM2
  • All are class 5 flexible conductor
  • Insulation grade is TI3
  • Sheathing grade is TM3

Note:

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 or UL83